{"id":434,"date":"2020-05-03T19:31:47","date_gmt":"2020-05-03T19:31:47","guid":{"rendered":"https:\/\/dxhelpdev.wpengine.com\/?post_type=epkb_post_type_1&#038;p=434"},"modified":"2020-08-21T18:39:36","modified_gmt":"2020-08-21T18:39:36","slug":"current-part-count-per-equipment","status":"publish","type":"epkb_post_type_1","link":"https:\/\/dxhelp.scytec.com\/?epkb_post_type_1=current-part-count-per-equipment","title":{"rendered":"Parts Views"},"content":{"rendered":"\n<h2 class=\"wp-block-heading\">Current Part Count Per Equipment<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">The <strong>Current Part Count Per Equipment<\/strong> View shows the part counts for the currently active part number on each piece of equipment.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">Configuration Options<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">The&nbsp;<strong>Equipment<\/strong>&nbsp;section is used to select the equipment that will be displayed in the View. The&nbsp;<strong>Dynamically Add New Equipment<\/strong>&nbsp;checkbox can be used to automatically add new equipment to the View.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">The following options are available in the <strong>Settings <\/strong>section:<\/p>\n\n\n\n<ul class=\"wp-block-list\"><li>The&nbsp;<strong>Font Size<\/strong>&nbsp;is used to set the font of the labels used on the View<\/li><li>The&nbsp;<strong>Reset Interval<\/strong>&nbsp;is used to determine the start and stop times for selecting the data for the chart.<ul><li><strong>Rolling<\/strong>&nbsp;will always count from the last X amount of hours.&nbsp;<\/li><li><strong>Set Interval<\/strong>&nbsp;will have a start time and then reset every X amount of hours from the specified start time.&nbsp;<\/li><li><strong>Current Shift<\/strong>&nbsp;will use the start time of the current shift<\/li><\/ul><\/li><\/ul>\n\n\n\n<p class=\"wp-block-paragraph\">All items have defaults allowing the View to be displayed quickly and easily.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"partcounts\">Part Counts<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">The <strong>Part Counts<\/strong> View displays the amount of good parts that have been recorded for the selected equipment for the selected time frame.&nbsp;<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">Configuration Options<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">The&nbsp;<strong>Equipment<\/strong>&nbsp;section is used to select the equipment that will be displayed in the View. The&nbsp;<strong>Dynamically Add New Equipment<\/strong>&nbsp;checkbox can be used to automatically add new equipment to the View.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">The following options are available in the <strong>Settings <\/strong>section:<\/p>\n\n\n\n<ul class=\"wp-block-list\"><li>The&nbsp;<strong>Font Size<\/strong>&nbsp;is used to set the font of the labels used on the View.<\/li><li>The&nbsp;<strong>Reset Interval<\/strong>&nbsp;is used to determine the start and stop times for selecting the data for the chart.&nbsp;<ul><li><strong>Rolling<\/strong>&nbsp;will always count from the last X amount of hours.&nbsp;<\/li><li><strong>Set Interval<\/strong>&nbsp;will have a start time and then reset every X amount of hours from the specified start time.&nbsp;<\/li><li><strong>Current Shift<\/strong>&nbsp;will use the start time of the current shift.<\/li><\/ul><\/li><li>The&nbsp;<strong>Legend<\/strong>&nbsp;is used to show or hide the legend.<\/li><\/ul>\n\n\n\n<p class=\"wp-block-paragraph\">All items have defaults allowing the View to be displayed quickly and easily.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"partsperhour\">Parts Per Hour<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">The <strong>Parts Per Hour<\/strong> View within the RTV is displayed as a target oriented screen that shows the actual part count in a clustered column or bar graph. Each machine has a blue indicator which is the <strong>Parts Per Hour Plan<\/strong>. This is the target number of parts that should have been made based on the amount of time that has passed. The Parts Per Hour Plan is calculated based on when a part start occurred or a shift change and the ideal time for that machine and part combination. The PPH Plan is a rolling target that will increase over time. You can choose to exclude certain planned downtime statues from the Parts Per Hour calculation. More information can be found&nbsp;<a href=\"https:\/\/dxhelp.scytec.com\/?epkb_post_type_1=parts-per-hour\">here<\/a>.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">For instance, if there is an ideal time of 10 minutes, the PPH Plan for that machine will increment by one every 10 minutes, so after 60 minutes there would be a PPH Plan of 6.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">PPH View Options<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">The&nbsp;<strong>Equipment<\/strong>&nbsp;section is used to select the equipment that will be displayed in the View. The&nbsp;<strong>Dynamically Add New Equipment<\/strong>&nbsp;checkbox can be used to automatically add new equipment to the View.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">There are two layouts for the View: <strong>Clustered Column<\/strong> or <strong>Single Column<\/strong>.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">The Clustered Column chart displays the target as a blue bar. The Single Column chart displays the target Parts Per Hour using a blue square indicator.<\/p>\n\n\n\n<figure class=\"wp-block-image\"><img loading=\"lazy\" decoding=\"async\" width=\"852\" height=\"292\" src=\"https:\/\/dxhelp.scytec.com\/wp-content\/uploads\/2020\/05\/image260676996.jpg\" alt=\"\" class=\"wp-image-702\" srcset=\"https:\/\/dxhelp.scytec.com\/wp-content\/uploads\/2020\/05\/image260676996.jpg 852w, https:\/\/dxhelp.scytec.com\/wp-content\/uploads\/2020\/05\/image260676996-300x103.jpg 300w, https:\/\/dxhelp.scytec.com\/wp-content\/uploads\/2020\/05\/image260676996-768x263.jpg 768w\" sizes=\"auto, (max-width: 852px) 100vw, 852px\" \/><figcaption>Clustered Column Example<\/figcaption><\/figure>\n\n\n\n<figure class=\"wp-block-image\"><img loading=\"lazy\" decoding=\"async\" width=\"671\" height=\"293\" src=\"https:\/\/dxhelp.scytec.com\/wp-content\/uploads\/2020\/05\/image816629185.jpg\" alt=\"\" class=\"wp-image-703\" srcset=\"https:\/\/dxhelp.scytec.com\/wp-content\/uploads\/2020\/05\/image816629185.jpg 671w, https:\/\/dxhelp.scytec.com\/wp-content\/uploads\/2020\/05\/image816629185-300x131.jpg 300w\" sizes=\"auto, (max-width: 671px) 100vw, 671px\" \/><figcaption>Single Column Example<\/figcaption><\/figure>\n\n\n\n<p class=\"wp-block-paragraph\">The&nbsp;<strong>Metric Options<\/strong>&nbsp;section is used to select the chart type along with the percentages that will be used to determine the color of the actual Part Count bar.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">The values specified for each of the levels is a percentage of the PPH plan.<\/p>\n\n\n\n<figure class=\"wp-block-image\"><img loading=\"lazy\" decoding=\"async\" width=\"401\" height=\"175\" src=\"https:\/\/dxhelp.scytec.com\/wp-content\/uploads\/2020\/05\/image1348454962.jpg\" alt=\"\" class=\"wp-image-705\" srcset=\"https:\/\/dxhelp.scytec.com\/wp-content\/uploads\/2020\/05\/image1348454962.jpg 401w, https:\/\/dxhelp.scytec.com\/wp-content\/uploads\/2020\/05\/image1348454962-300x131.jpg 300w\" sizes=\"auto, (max-width: 401px) 100vw, 401px\" \/><\/figure>\n\n\n\n<p class=\"wp-block-paragraph\">The following options are available in the <strong>Settings <\/strong>section:<\/p>\n\n\n\n<ul class=\"wp-block-list\"><li><strong>Font Size<\/strong>:&nbsp;Use this setting to customize the size of the font. The larger the number the larger the text will be.<\/li><li><strong>Legend<\/strong>: This allows the option to display the legend or not. If on, it will allow the users to see what the colors of the bars mean.<\/li><\/ul>\n","protected":false},"excerpt":{"rendered":"<p>Current Part Count Per Equipment The Current Part Count Per Equipment View shows the part counts for the currently active part number on each piece of equipment. Configuration Options The&nbsp;Equipment&nbsp;section is used to select the equipment that will be displayed in the View. The&nbsp;Dynamically Add New Equipment&nbsp;checkbox can be used to automatically add new equipment [&hellip;]<\/p>\n","protected":false},"author":4,"featured_media":0,"comment_status":"closed","ping_status":"closed","template":"","meta":{"footnotes":""},"epkb_post_type_1_category":[45,43,29,107],"epkb_post_type_1_tag":[],"class_list":["post-434","epkb_post_type_1","type-epkb_post_type_1","status-publish","hentry","epkb_post_type_1_category-managers","epkb_post_type_1_category-operators","epkb_post_type_1_category-rtv-views","epkb_post_type_1_category-viewing-data"],"_links":{"self":[{"href":"https:\/\/dxhelp.scytec.com\/index.php?rest_route=\/wp\/v2\/epkb_post_type_1\/434","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/dxhelp.scytec.com\/index.php?rest_route=\/wp\/v2\/epkb_post_type_1"}],"about":[{"href":"https:\/\/dxhelp.scytec.com\/index.php?rest_route=\/wp\/v2\/types\/epkb_post_type_1"}],"author":[{"embeddable":true,"href":"https:\/\/dxhelp.scytec.com\/index.php?rest_route=\/wp\/v2\/users\/4"}],"replies":[{"embeddable":true,"href":"https:\/\/dxhelp.scytec.com\/index.php?rest_route=%2Fwp%2Fv2%2Fcomments&post=434"}],"version-history":[{"count":0,"href":"https:\/\/dxhelp.scytec.com\/index.php?rest_route=\/wp\/v2\/epkb_post_type_1\/434\/revisions"}],"wp:attachment":[{"href":"https:\/\/dxhelp.scytec.com\/index.php?rest_route=%2Fwp%2Fv2%2Fmedia&parent=434"}],"wp:term":[{"taxonomy":"epkb_post_type_1_category","embeddable":true,"href":"https:\/\/dxhelp.scytec.com\/index.php?rest_route=%2Fwp%2Fv2%2Fepkb_post_type_1_category&post=434"},{"taxonomy":"epkb_post_type_1_tag","embeddable":true,"href":"https:\/\/dxhelp.scytec.com\/index.php?rest_route=%2Fwp%2Fv2%2Fepkb_post_type_1_tag&post=434"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}